Calculator · Free tier← All calculators

Stormwater Attenuation Tank Quantity Calculator

Underground stormwater attenuation tank with inlet, outlet, and overflow. Computes excavation, granular surround, tank build (concrete or geocellular), and disposal.

Slug · attenuation_tank · v1.0

Loading assembly schema…

Stormwater Attenuation Tank — a worked example, measured four ways

The same assembly at default dimensions, rendered as a Bill of Quantities under each measurement standard. Switch the standard to see how the bill changes. Change the inputs in the calculator to compute your own.

CESMM4 · 9 items · units m³, m²

CodeDescriptionUnitQuantity
E.4.2.5General excavation, maximum depth 2-5m, commencing from existing ground levelm³709.8
E.5.3Disposal of excavated material off-sitem³485.1
E.7.1Preparation of excavated surfaces, formationm²234
E.6.3.2Filling, imported selected granular material, Class 6N to SHWm³158.4
E.6.2.1Filling, excavated materialm³224.7
L.5.1Granular bedding to pipe, 20mm single-size aggregatem³29.7
L.5.2Granular surround to pipe, 20mm single-size aggregatem³81
E.7.2Geotextile filter, 200 g/m², including lapsm²545.69
I.8.1Modular geocellular attenuation crates, void ratio 95%m³216
● MATERIAL SCHEDULE

Procurement take-off: the total quantity to order of each material, from the same compute. Supplier-neutral, so you buy anywhere.

  • Attenuation Crate216 m³
  • Disposal485.1 m³
  • Excavation General709.8 m³
  • Fill General224.7 m³
  • Fill Selected158.4 m³
  • Formation Prep234 m²
  • Geotextile Filter545.69 m²
  • Pipe Bedding29.7 m³
  • Pipe Surround81 m³

Illustrative example at default dimensions · engine ref e306df · not a tendered quantity