Reinforced Soil Wall (RSW) — a worked example, measured four ways

The same assembly at default dimensions, rendered as a Bill of Quantities under each measurement standard. Switch the standard to see how the bill changes. Change the inputs in the calculator to compute your own.

CESMM4 · 9 items · units m³, m², m

CodeDescriptionUnitQuantity
E.4.2.1General excavation, maximum depth n.e. 0.25m, commencing from existing ground level21.52
E.5.3Disposal of excavated material off-site18.72
E.6.3.2Filling, imported selected granular material, Class 6I to SHW1080
E.6.2.1Filling, excavated material2.8
F.1.1.1In-situ concrete blinding, C8/10, thickness 100mm18.72
E.7.2Geotextile separator, 200 g/m², including laps198
E.8.8Geogrid reinforcement, uniaxial polyester, Tensar RE540/580/740, T_d ≥ 80 kN/m, horizontal reinforcement layer, 8 layers @ 0.75m vertical spacing, 4.50m length (CESMM4 has no dedicated rule; measured under Class E §E.8 stabilisation)1440
E.8.4Reinforced soil wall, precast concrete facing panel, T-shape cruciform 180mm thick, C40/50 concrete, total wall height 6.00m, Class 6I reinforced fill behind (SHW Cl. 624), reinforced soil wall, precast concrete facing panels240
E.8.7Reinforced soil wall, steel tie strip, 50mm × 4mm, hot-dip galvanised to BS EN ISO 1461, 4.50m embedment length, cast-in panel clutch fixing, reinforced soil wall steel tie stripsm2160
● MATERIAL SCHEDULE

Procurement take-off: the total quantity to order of each material, from the same compute. Supplier-neutral, so you buy anywhere.

  • Concrete Blinding18.72
  • Disposal18.72
  • Excavation General21.52
  • Fill General2.8
  • Fill Selected1080
  • Geogrid1440
  • Geotextile Separator198
  • Rsw Facing Panel240
  • Rsw Tie Strip2160 m